datex_top.gif (13366 bytes)

contact_us_nav.gif (2943 bytes)

Products & Services
btn_1.gif (153 bytes) Dedicated Servers
btn_1.gif (153 bytes) Colocation Services
btn_1.gif (153 bytes) Shared Hosting
btn_1.gif (153 bytes) E-commerce Hosting
btn_1.gif (153 bytes) Reserve / Park Domain
btn_1.gif (153 bytes) Remote Admin Services
compare1.gif (229 bytes) Shared Hosting Chart
orderbut.gif (221 bytes) Order Online Today
Enabling Technology
btn_1.gif (153 bytes) Installed Technology
btn_1.gif (153 bytes) High Availability Network
btn_1.gif (153 bytes) Online Support
About Us
btn_1.gif (153 bytes) Mission
btn_1.gif (153 bytes) Virtual Tour
btn_1.gif (153 bytes) Customers
btn_1.gif (153 bytes) Careers @ datex
Partners
btn_1.gif (153 bytes) Reseller Partners
Order Today
Contact Us



topnav_support.GIF (470 bytes)topnav_host.GIF (649 bytes)topnav_tech.GIF (635 bytes)topnav_order.GIF (632 bytes)topnav_contact.GIF (507 bytes)

Data Centers and
High Availability Network

At the heart of Datex' advanced Internet Operations lie the Datex Data Centers. These hardened and secure facilities are geographically and network diverse. They are located in ultra-secure buildings maintained by 24x7 onsite personnel. Each data center contains backup and disaster recovery systems to ensure the safety and availability of customers' applications, services and data.

A Typical Data Center Includes:

Power: Power is supplied via two separate 34,800-volt power lines of electricity feeding from two separate city grid systems with two points of entry into the building. If for any reason there is a break in power, all critical equipment in the building can be run by UPS battery power until the five (5) 1,100-kilowatt generators begin to operate. These generators start within 5-7 seconds. Bare metal testing of the generators is conducted at least 2 times per month. Fuel for the generators is stored in three (3) 30,000 gallon underground storage tanks which provide enough fuel to operate the building at 100% load for 30+ days.

UPS: All critical equipment loads are fed from the Emerson UPS system. The UPS system consists of five (5) 560 KVA modules and three (3) battery strings to ensure that critical loads never experience an interruption in power.

Central Plant, N+3 redundancy: The Chilled Water central plant consists of three (3) 1,000 ton and two (2) 500 ton “Trane” centrifugal chillers with four (4) 1,500 ton ceramic cooling towers. Cooling the entire building on a hot summer day typically requires 1,300 tons of cooling, providing N+3 redundancy within existing chiller central plant.

Fire Detection: VESDA Laser Plus

Sprinklers: Equipment areas are protected by a pre-action wet pipe system. The system detects any water leakage within the building based on the level of condensation on pipes within the building. Excess condensation immediately triggers alerts to the building operations staff.  For further prevention the multi-zoned sprinkler systems are designed to prevent fires within only the areas of the data center that are affected. The sprinkler system is powered by one (1) 250 hp electric fire pump and one (1) 150 hp diesel driven pump.

Facility Security: Our high security facilities are accessible by authorized personnel only. Rack access is also limited to authorized personnel only. The data center is manned 24x7 by uniformed security guards and is equipped with video surveillance cameras and monitors. All security data is backed up and stored offsite.

Monitoring: 24x7 monitoring is provided by BroadSpire’s Network Operations Staff.

Furthermore, the data centers are all fully enmeshed with Datex Intelligent Network Technology, capable of delivering 99.999% uptime and minimum latency for your Internet Applications.

Datex currently has five Data Centers, located in Los Angeles, New York, London and Frankfurt.

Los Angeles
Los Angeles

newyork.gif (9850 bytes)
New York

london.gif (9645 bytes)
London

NOT PICTURED

Frankfurt

contact_today.GIF (1302 bytes)


guarantee_bot.GIF (1233 bytes)

botnav_tour.GIF (310 bytes)botnav_services.GIF (540 bytes)botnav_news.GIF (445 bytes)

 

Acceptable Uses Policy
Copyright 2000-2004 BroadSpire, Inc.. All rights reserved.
Ph: 1-213-986-1050    |    Fax: 1-213-688-7791